Why does my gas detector show a percentage but not trigger the alarm?

For users of Cuby Protect and Cuby Helios

What does the gas percentage in the app mean?

The percentage does not indicate how much gas is in the air. It is a progress bar toward the alert threshold you configured, based on the LEL (Lower Explosive Limit).

The alarm triggers when it reaches 100% of your configured threshold and stays there for at least 20 seconds.

What to do based on what you see in the app

App shows Recommended action
Less than 50% Monitor only
50 – 80% Consider ventilating the space
More than 80% Ventilate and locate the source
100% Alarm sounds — act according to protocol

 

Important

If the percentage stays constant without dropping, even if it hasn't reached 100%, ventilate and check immediately. It may indicate an active leak.

If you smell gas, don't wait for the alarm. Ventilate, shut off the valve, and move away from the area.